Wastewater Calculator

Calculate activated sludge F/M, hydraulic and solids retention time, BOD loading, and aeration tank solids inventory.

Result
—

How to calculate

Daily BOD load is concentration times flow. Divide influent load by aeration MLVSS inventory for F/M. Divide aeration volume by incoming flow for retention time, and divide biomass inventory by solids mass leaving each day for solids retention time.

Worked example

Use Influent flow to aeration (m³/day) 1000 · Aeration tank volume (m³) 500 · BOD₅ entering aeration (mg/L) 200 · Treated effluent BOD₅ (mg/L) 20 · Aeration MLVSS (mg/L) 2000 · Waste sludge flow (m³/day) 10 · Waste sludge VSS (mg/L) 8000 · Treated effluent VSS (mg/L) 20. The result is ≈ 0.2 day⁻¹.

Input and result notes

Uses a steady-state aeration tank balance with treated flow equal to influent minus waste flow. Inventory is based on aeration volume only. Enter consistent sampling data for the same process.

Michigan EGLE wastewater operator formulas

Related calculators