How to calculate
Multiply the blank-minus-sample difference by titrant normality and 8,000, then divide by sample volume.
Worked example
Use Ferrous ammonium sulfate for blank (mL) 20 · Ferrous ammonium sulfate for sample (mL) 12 · Titrant normality (eq/L) 0.1 · Sample volume (mL) 40. The result is ≈ 160 mg O₂/L.
Input and result notes
Use values from the ferrous ammonium sulfate titration procedure and account for any sample dilution separately.
EPA chemical analysis methods for water and wastes