Faraday's Law Calculator

Calculate average induced voltage from magnetic flux change, elapsed time and coil turns using Faraday’s law of induction.

Result
—

How to calculate

Multiply the signed change in flux per turn by turn count and divide by elapsed time. Reverse the sign for Lenz’s law. With field inputs, multiply each field by loop area and the cosine of the angle to the loop normal.

Worked example

Use Magnetic flux input Known signed flux change per turn · Number of identical turns 10 · Elapsed time (s) 0.2 · Final minus initial flux per turn (Wb) 0.004. The result is ≈ -0.2 V.

Input and result notes

Use a consistent loop orientation. A finite interval gives mean emf. The coil option assumes the field is uniform across each turn.

OpenStax Faraday’s induction law

Related calculators