Solenoid Inductance Calculator

Estimate solenoid inductance or winding turns from coil dimensions and relative permeability. Calculate stored energy at a given current.

Result
—

How to calculate

Multiply permeability by coil cross-sectional area and the square of the turn count, then divide by wound length. For target inductance, solve for turns and round up.

Worked example

Use Find Inductance from turns and dimensions · Length of wound coil 10 · Mean coil diameter 4 · Coil dimension unit Centimeters · Effective relative permeability 1 · Inductance unit Millihenries · Wire turns 200. The result is ≈ 0.631654682 mH.

Input and result notes

The equation approximates a long coil with a uniform field. Short coils, gaps, magnetic saturation, and winding geometry affect actual inductance.