Welding Calculator

Estimate weld force from effective throat area and an entered stress. Solve for length for a 90° fillet or a butt weld.

Result
—

How to calculate

For an equal-leg fillet, divide the leg by the square root of two for the geometric throat. For a butt weld, enter its effective throat. Multiply total effective area by the applicable stress.

Worked example

Use Weld geometry 90° fillet · Find Force from effective length · First fillet leg or butt throat (mm) 5 · Identical weld lines 1 · Applicable throat stress (MPa) 70 · Effective length per line (mm) 100. The result is ≈ 24.74873734153 kN.

Input and result notes

Enter the stress and effective length from your design method. The force estimate assumes uniform loading and identical weld lines. Consider weld direction, eccentricity, base metal, weld quality, and connection details in the actual design.