Porosity and Permeability Calculator

Find intrinsic permeability from Darcy flow in a saturated sample. Calculate porosity from pore volumes, dry density, or mean tracer travel time.

Result
—

How to calculate

For a horizontal sample, multiply volume flow, viscosity, and flow length. Divide by the sample area and pressure drop to find intrinsic permeability. Report pore volume as a fraction of bulk volume, or subtract the dry bulk to grain density ratio from one. Connected porosity from a conservative tracer is the flow rate times mean travel time divided by bulk volume.

Worked example

Use Input method Darcy flow and optional tracer time · Sample flow length (m) 0.1 · Sample flow area (m²) 0.01 · Volume flow (m³/s) 0.00001 · Dynamic viscosity (Pa·s) 0.001 · Pressure drop along flow (Pa) 10000. The result is ≈ 1e-11 m².

Input and result notes

Use steady single-phase flow and dynamic viscosity at test temperature. A tracer estimates the volume participating in flow, which can be smaller than total pore volume.

USGS groundwater hydraulics

USGS tracer tests for effective porosity

Related calculators