How to calculate
Divide neck opening area by cavity volume times effective neck length in SI units. Take the square root and multiply by sound speed divided by two π. The effective length adds an end correction to the physical neck length. The automatic circular option adds 1.7 neck radii total.
Worked example
Use Cavity input Known volume · Air cavity volume (L) 10 · Neck opening Circular with approximate end correction · Neck inside diameter (mm) 50 · Physical neck length (mm) 20 · Speed of sound (m/s) 343. The result is ≈ 96.75851357844 Hz.
Input and result notes
Use internal dimensions and passable neck area. The circular end correction is an approximation. Flanges, nearby boundaries, and neck geometry can change it, so use a measured or modeled correction when available.
UNSW explanation of Helmholtz resonance