How to calculate
Multiply input voltage by the secondary-to-primary turns ratio and by duty cycle divided by one minus duty cycle. Check conduction from average current and half the modeled ripple.
Worked example
Use Find Duty cycle from output voltage · DC input voltage (V) 48 · Output voltage magnitude (V) 12 · Output load current (A) 2 · Switching frequency (kHz) 100 · Primary magnetizing inductance (µH) 100 · Effective output capacitance (µF) 100 · Efficiency for input current estimate (%) 90 · Secondary turns per primary turn 0.25. The result is ≈ 50 %.
Input and result notes
The model uses ideal continuous-conduction equations and reports when the selected load crosses the conduction boundary. Verify component and controller limits separately, including parasitic voltage spikes and transient behavior.
Texas Instruments continuous-conduction flyback design