Crosstalk Calculator

Estimate capacitive crosstalk from a signal edge, mutual capacitance, and the victim resistance and capacitance. Includes a thin-wire geometry approximation.

Result
—

How to calculate

Model the transition as a linear ramp. Capacitive coupling drives a current into the victim’s resistive and capacitive load. Evaluate the RC response at the end of the edge.

Worked example

Use Coupling model Known mutual capacitance · Aggressor voltage step (V) 3.3 · Linear rise time (ns) 2 · Victim termination resistance (Ω) 50 · Mutual capacitance (pF) 1 · Victim load capacitance to ground (pF) 2. The result is ≈ 0.082499866383 V.

Input and result notes

This is a lumped capacitive estimate for an electrically short route. The geometry option approximates conductor cross sections with round wires over a ground plane. Distributed reflections, near-end or far-end inductive coupling, and actual PCB stackup can change the result.

TI high-speed design reference on capacitive and inductive coupling