How to calculate
In the standard astable circuit, the timing capacitor charges through RA and RB and discharges through RB. Each interval uses a factor of ln 2. The monostable capacitor charges from near zero to two thirds of the supply, giving ln 3 times RC.
Worked example
Use 555 operating mode Astable oscillator from timing components · Capacitance (µF) 1 · Timing resistor RA (Ω) 1000 · Timing resistor RB (Ω) 2000. The result is ≈ 288.5390081778 Hz.
Input and result notes
The standard two-resistor astable circuit has an output high duty cycle above 50%. Actual timing depends on the device, component tolerances, and the supply conditions.
Texas Instruments NE555 datasheet for astable and monostable connections