555 Timer Calculator

Calculate 555 timer frequency, duty cycle, pulse width, or timing resistor values for astable and monostable circuits.

Result
—

How to calculate

In the standard astable circuit, the timing capacitor charges through RA and RB and discharges through RB. Each interval uses a factor of ln 2. The monostable capacitor charges from near zero to two thirds of the supply, giving ln 3 times RC.

Worked example

Use 555 operating mode Astable oscillator from timing components · Capacitance (µF) 1 · Timing resistor RA (Ω) 1000 · Timing resistor RB (Ω) 2000. The result is ≈ 288.5390081778 Hz.

Input and result notes

The standard two-resistor astable circuit has an output high duty cycle above 50%. Actual timing depends on the device, component tolerances, and the supply conditions.

Texas Instruments NE555 datasheet for astable and monostable connections

Related calculators